Skip to content

Machine monitoring software compared:The honest comparison.

Where Atlas Edge stands next to the other ways a plant can watch its machines, including where it does not win yet. Gateways are compared by name, spec by spec; software by the kind of product it is.

YesPartly, or with add-onsNo

01What else is out there

Five other ways to watch a machine.

Most plants that watch their machines buy one of these, or stitch two or three together. Each is good at its own part. The question is what is left over between a reading and a signed-off repair.

02Side by side

16 questions. Straight answers.

Atlas Edge answers yes to 10 of them, partly to 3 and no to 3. The noes are real: they are on the list below of what we are building next.

Can it…Atlas EdgeIndustrial gatewayConnectivity softwareSensor-based monitoringMachine-monitoring softwareMaintenance software (CMMS)
Getting the data
Reads the controllers already on the machinesYesSix protocol families: MTConnect, OPC UA, Modbus, EtherNet/IP, MQTT, HTTPPartlyThe ports are there; the reading is yours to programYesHundreds of drivers, the widest coveragePartlyMostly its own sensors; one vendor adds a PLC readerYesCNC controllers; clamps on older machinesPartlyThrough paid connectors or add-on sensors
Number of controller types it can readPartlyNo native Siemens S7, PROFINET, BACnet or FANUC FOCAS yetPartlyDepends on the software you addYes150 to 300 driversNoPartlyDeep on CNC (FOCAS and more), thinner on utilitiesNo
Keeps every reading through an internet outageYesStored on the box, sent after, exactly oncePartlyIf you build itYesStore and forward is commonPartlyBuffered in the receiver, usually for a limited timePartlyVariesNo
Can stop a machine when a limit is crossedPartlyE1 Reflex only: it asks the machine's own controller for a feed hold. E1 alerts your teamYesWith outputs and logic you programPartlyCan write a stop command where writes are allowedNoAlerts peopleNoAlerts peopleNo
Spotting trouble
Learns each machine's normal and flags a driftYesPer machine and signal, against its load, after about 72 running hoursNoPartlyAnomaly detection on higher tiersYesTheir core strengthPartlyMostly limits and production alertsPartlyAdd-on sensors with limits
Vibration spectra and named fault diagnosisNoJudges the vibration level against ISO 20816-3 zones and the machine's own reference. E1 Reflex is planned with vibration inputs that work out frequency bands on the box; no named faultsNoNoYesSpectra and ultrasound up to 64–100 kHz: bearings, alignment, lubricationNoNo
Alarms that hold, escalate and email the right peopleYesHold time, deadband, escalation, acknowledgement on the recordPartlyBasic alarms on somePartlyBasic alertsYesYesPartlyFrom meter readings or add-on sensors
Fixing it, on the record
Work orders with verify and approve stepsYesVerified, approved, done, each step signedNoNoPartlyOne vendor has its own CMMS; most hand off to oneNoProduction job tracking, not maintenance ordersYesTheir core strength, with parts and schedules
Lockout/tagout tied to the order, PIN-signedYesLocks only under an approved order; release records the causeNoNoNoNoPartlyLOTO checklists, not tied to live machine state
Preventive schedules and spare partsNoNot yetNoNoPartlyNoYes
Activity log of every change, in sentencesYesNoPartlySystem logsPartlyPartlyYes
Proving it
Availability, MTBF, MTTR, OEE and downtime by causeYesPer machine, area and plant, from live data and the lockout trailNoNoPartlyAsset health; one vendor adds OEEYesOEE and downtime are their corePartlyMTBF and MTTR from work orders, no live data
Reports and exports you can check in ExcelYesWorkbooks with live formulas, CSV, a read-only data APINoPartlyData out, no reportsPartlyYesYes
Buying it
Customers you can callNoOne pilot plant so farYesYesYesYesYes
Phone appPartlyiPhone and Android: a demo plant and a read-only live view. Not in the app stores yetNoNoYesPartlyTablets on the floor; apps varyYes
One product from the machine to the signed-off repairYesBox, warnings, work orders, lockout and KPIs togetherNoNoPartlyOne vendor bundles sensors, CMMS and OEEPartlyNo

Swipe the table sideways to see every column.

03The box

E1 against six gateways on sale.

E1 and E1 Reflex next to six well-known industrial gateways, spec by spec, from each maker's own datasheet.

SpecE1E1 ReflexRevolution Pi Connect 5Siemens SIMATIC IOT2050 AdvancedMoxa UC-8220HMS Ewon Flexy 205Advantech ECU-1251TLTeltonika TRB246
ProcessorQuad-core, 1.4 GHzQuad-core, 1.4 GHzQuad-core Cortex-A76 (Raspberry Pi CM5)Quad-core Cortex-A53 (TI AM6548)Dual-core Cortex-A7, 1 GHzNot publishedSingle-core Cortex-A8, 800 MHzMIPS, 580 MHz
Memory, storage4 GB, 32 GB8 GB, 64 GB4–8 GB2 GB, 16 GBUp to 2 GBNot published256 MB128 MB, 16 MB flash
Network2 × Gigabit Ethernet; Wi-Fi and Bluetooth LE planned2 × Gigabit Ethernet; Wi-Fi and Bluetooth LE planned2 × Gigabit Ethernet2 × Gigabit Ethernet2 × Gigabit Ethernet; 4G built in4 × 100 Mb Ethernet; 4G by card2 × 100 Mb Ethernet; 4G option1 × 100 Mb Ethernet; 4G built in
Serial2 × RS-485, each isolated and surge-protected4 × RS-485, each isolated and surge-protectedRS-485 optional1 × RS-232/422/4852 × RS-232/422/485; CANBy extension card4 × RS-232/485, 3 kV isolatedRS-232 and RS-485
Inputs and outputs4 isolated 24 V digital inputs; no outputs8 isolated digital inputs, 2 × 4–20 mA, 2 vibration inputs, stop-request relaysThrough expansion modulesArduino-style header, not 24 V field I/O4 isolated digital inputs, 4 outputs2 digital inputs, 1 output; I/O cardsNone3 digital in/out, 1 analog input
Operating temperatureTarget −20 to +60 °CTarget −25 to +50 °C, coated−25 to +55 °C0 to +50 °C−40 to +70 °C (4G model)−25 to +60 °C−40 to +70 °C−40 to +75 °C
Software in the boxAtlas Edge agent and dashboard: six protocols, set up from the dashboard, signed updates with rollbackAs E1, plus stop requests decided on the box that carry on through a restart or updateRaspberry Pi OS; Node-RED and CODESYS supportedIndustrial Linux image you install and programMoxa Industrial Linux you programTalk2M remote-access cloud and scriptingWISE-EdgeLink protocol drivers, some paidRutOS with Modbus, OPC UA and MQTT; RMS cloud

Swipe the table sideways to see every column.

E1 aheadIsolation and surge protection on every RS-485 port, two on E1 and four on E1 Reflex. More memory and storage than most here, with E1 Reflex at 8 GB and 64 GB. And the only box that arrives with maintenance software, set up from a dashboard, instead of a blank Linux system.

E1 behindThe Revolution Pi Connect 5 has a faster processor, and Advantech rates its serial isolation higher. Moxa, Advantech and Teltonika run down to −40 °C, where E1 targets −20 to +60 °C and E1 Reflex −25 to +50 °C; neither has 4G. Plain E1 has no analog inputs; E1 Reflex adds two 4–20 mA inputs.

E1 Reflex can also ask a machine's own controller to stop (a feed hold or cycle stop) when a limit you set is crossed. It decides on the box, so it works with the internet down. It is a stop request, not a safety device.

04Plainly

Where we're ahead. Where we're not, yet.

Ahead

  • From reading to repair in one productThe box, the warning, the work order, the lockout and the monthly numbers share one record. Elsewhere that is two or three products and the joins between them.
  • Uses what is already on the machineControllers, meters and drives. Many signals need no new sensor at all, so a whole shop area costs one box, not a sensor per machine.
  • Figures you can checkEvery reading arrives exactly once and carries its quality. Missing data shows as missing, never as zero, and every report opens in Excel with its formulas.
  • Repairs done by the bookVerified, approved, locked out under the order with a PIN, released with the cause. Every step lands in an activity log that reads as sentences.
  • A box that looks after itselfSigned updates that roll back on their own if the new version fails, and its own health (temperature, disk, every connection) on the dashboard.

Behind, and what we are doing

  • No vibration analysisBands planned on E1 ReflexWe read a vibration level from a standard sensor and judge it hour by hour against the load. We do not name a fault such as bearing wear, which sensor-based systems catch weeks earlier. E1 Reflex is planned with two vibration-sensor inputs that work out the overall level and frequency bands on the box.
  • Fewer controller typesAdded as plants askSix protocol families. No native Siemens S7, PROFINET, BACnet, FANUC FOCAS or IO-Link yet, where connectivity suites offer 150 to 300 drivers.
  • No analog inputs on E1On E1 ReflexE1 has isolated RS-485 and four digital inputs, but no 4–20 mA; such sensors go through a small Modbus I/O module. E1 Reflex adds two isolated 4–20 mA inputs.
  • No preventive schedules or spare partsNot built yetWork orders start from a warning or a person. Calendar and run-hour schedules and a parts store are what a CMMS still does better.
  • One pilot, no case studiesPilot runningThe software runs on one working shop floor. There are no published results or customers to call yet.
  • Phone app not in the stores, no WhatsApp or SMSStores nextThe phone app, for iPhone and Android, has a demo plant to try and a read-only live view of your own dashboard through a data API key, but it is not in the app stores yet. Alerts go by email and in the dashboard.

05Fair advice

When something else is the better buy.

We would rather tell you now than lose your trust later. If one of these is you, start there, and talk to us when you want the rest joined up.

Bring your plant alive.

A gateway per shop area, the controllers you already have, and your first monthly report in the inbox on the 1st. Tell us about your floor.