Predictive maintenance for buildings & data centres.
A chiller using more energy every week for the same cooling, before it fails on the hottest day.
Who it is for
Commercial buildings, hospitals, malls and data centres with central plant rooms.
Next
Next on our list, where we go after the pilot. The pumps, motors and compressors in buildings & data centres plants are machine classes Atlas Edge already models; machines such as chillers and air handling units need their own signals and limits first. We are looking for design partners: plants that want to shape it and run it first.
What it listens to
Chillers
Watches · kW per ton
Air handling units
Watches · Fan vibration
Diesel generators
Watches · Run hours
UPS and pumps
Watches · Load
What goes wrong first
The first sign, and how it is caught.
| Fault | The first sign | How Atlas Edge watches it |
|---|---|---|
| Chiller fouling or low refrigerant | kW per ton of cooling rising week over week | Weekly trend in the KPI view and the monthly report |
| Air-handler fan bearing wear | Fan vibration out of its zone | ISO 20816-3 vibration zone and change from its reference |
| Pump wear | Motor power above normal for the same flow | Learned normal for its load: Watch, then Investigate |
| Generator not ready | Run hours and battery out of step with the test schedule | Alarm at your limit, raised only after a hold time |
How a zone is judged: ISO 20816-3 vibration zones. Why alarms wait: hold time and deadband.
Same platform underneath
Everything our pilot floor runs on, for your floor.
Live views
Every machine's readings as they happen, beside a cutaway drawing of it, on every screen at once.
Load-aware anomaly detection
Learns how each reading moves with the load and says Normal, Watch or Investigate, with the reason in plain words.
Alarms that hold
A condition must hold before it raises, escalates from warning to critical, and clears only past a deadband.
Work orders & LOTO
Verified, approved, PIN-gated lockouts, and the cause of every stop recorded on release.
KPIs & OEE
Availability, MTBF, MTTR, OEE, energy and downtime by cause, per machine, area and plant.
Monthly report
A performance report with an Excel workbook in the inbox on the 1st of every month.
Reads FANUC, SINUMERIK, Mazak, Okuma and Haas over MTConnect, Siemens S7-1500 over OPC UA, Rockwell Logix PLCs over EtherNet/IP, energy meters and drives over Modbus RTU/TCP, and sensors over MQTT. Every feature
Buildings & data centres
Common questions.
Does Atlas Edge work with chillers?
Not yet as a machine class of its own: buildings & data centres is next on our list. Their pumps, motors and compressors can be monitored as those classes, and we are looking for design partners to build the rest with.
Do we have to replace our PLCs or controllers?
No. Atlas Edge reads from what you already have, over Modbus RTU/TCP, MTConnect, OPC UA, EtherNet/IP, MQTT or HTTP/JSON, through one edge gateway per shop area, and never changes a program or setting. Only the E1 Reflex model can also ask a machine to stop, when a limit you set is crossed.
What does it catch in buildings & data centres?
A chiller using more energy every week for the same cooling, before it fails on the hottest day. It learns each machine's normal from its own running hours, flags a drift in plain words and projects the trend to the warning limit, labelled an estimate.
How do we start?
Write to us about your plant and its machines. Design partners in buildings & data centres get it first and shape what it watches.
Guides
- Monitor old CNC machines without replacing the controllerRead
- Predictive maintenance for machine shops: a plain guideRead
- ISO 20816-3 vibration zones: what A, B, C and D meanRead
- How to calculate OEE (and the mistakes that inflate it)Read
- MTBF and MTTR: what they mean and how to calculate themRead
- Machine downtime tracking: record why every stop happenedRead
- Machine utilisation: measure running, idle and off timeRead
- Nuisance alarms: stop chattering with a hold time and deadbandRead
- OEE calculator: availability, performance and qualityRead
- MTBF and MTTR calculator for machinesRead
- MTConnect vs OPC UA: which to use for machine dataRead
- Modbus energy monitoring: meter a machine per circuitRead
- MachineMetrics alternative: how Atlas Edge comparesRead
- Evocon alternative: how Atlas Edge comparesRead
Other industries
Bring your plant alive.
A gateway per shop area, the controllers you already have, and your first monthly report in the inbox on the 1st. Tell us about your floor.