Industrial IoT data pipeline:Engineered like infrastructure.
A plant’s data has to arrive exactly once, be stored without loss, be judged on its quality, and be kept away from anyone who should not see it. This is how.
01 · Telemetry pipeline
From register to every screen.
In the shop area
Edge agent
Reads the controllers and meters already on the floor, as often as once a second.
- Six protocol families
- Keeps readings through outages
- Sends each reading once
- Reports its own health
In the dashboard
Taking it in
- 1Checks the boxeach box sends only for its own machines
- 2Counts it oncenothing doubled after an outage
- 3Files itevery reading to its machine and signal
- 4Judges its qualitygood, uncertain or bad
Stored first. The box lets go of a reading only once the dashboard has it safe.
Live screens
Every screen within the second. A dropped connection picks up where it left off.
dashboard · phone · control room
Rules and alarms
Automation rules and alarms judge each live reading as it lands.
alarm · work order · lockout
History
Every reading kept, by the minute and by the hour, for the trends, KPIs and reports.
trends · KPIs · monthly report
Kept until it is safe
The box holds every reading until the dashboard has stored it, and sends it again if it has not.
Never counted twice
Readings sent again after an outage are recognised, so nothing is doubled.
Quality on every reading
Good, uncertain or bad. Implausible values are kept and counted, and never drive a rule or alarm.
Nothing invented
Missing data is shown as “No data recorded”. Never a zero, never filled in.
02 · Edge agent
Speaks the machine’s language.
A small program runs on the box in each shop area. It reads the controllers and meters already there, and keeps every reading until the dashboard has it, through any network outage.
| Protocol | Reads |
|---|---|
| Modbus RTU / TCP | Energy meters, drives, PLC registers Over RS-485 or the plant network |
| MTConnect | FANUC, SINUMERIK, Mazak, Okuma, Haas From the machine's own MTConnect agent |
| OPC UA | SINUMERIK, S7-1500, the FANUC option The server's own quality carried onto each reading |
| EtherNet/IP | Rockwell ControlLogix, CompactLogix, Micro800 Tags read by name |
| MQTT | Wireless sensors, IoT gateways, edge nodes Plain JSON or Sparkplug B |
| HTTP / JSON | Devices with a web endpoint Values read from the device's own page |
6
protocol families
1 s
fastest reading
0
duplicates after an outage
03 · Storage
Every reading kept, sized to last.
Three levels of detail. The finest ages out on a schedule without the plant noticing; the hourly record that every report is built from stays for good.
- Kept2 days
Every reading
Full detail, for looking closely at a single event.
- Kept7 days
By the minute
Each signal's average, highs and lows, minute by minute, for the past week.
- KeptKept for good
By the hour
What every KPI, trend and monthly report is built from.
04 · Security
Locked down by default.
Hardened pages
Strict browser security on every page, so the dashboard cannot be framed, injected into or sniffed.
Scoped keys
Each box's key sends only for its own machines; data keys read only the data and areas you allow.
Least access
The dashboard itself can only read and write records, never change or wipe the database.
PINs and limits
Lockouts and other field actions need a PIN; repeated failed attempts are blocked.
Roles that hold
Every request is checked against the person's role, and the most powerful account cannot be changed by anyone else.
Everything recorded
Every action, export and key change is kept in an activity log that reads as sentences.
05 · Data API
Your data, anywhere you work.
A read-only API (JSON or CSV) that Power BI, Excel or your own systems can read. It reads through the same code as the dashboard, so a figure there is the figure on screen.
- /api/v1/units
- /api/v1/telemetry
- /api/v1/kpis
- /api/v1/alarms
- /api/v1/work-orders
JSON or CSV · paged · times in the plant’s time zone · missing data stays empty
$ curl -H "Authorization: Bearer $ARK" \
".../api/v1/telemetry?unit=mct-101-a&metric=power_kw&resolution=hour"
{
"dataset": "telemetry",
"time_zone": "Asia/Kolkata",
"count": 24,
"next_cursor": null,
"data": [
{
"unit_id": "mct-101-a",
"metric": "power_kw", "measure_unit": "kW",
"time": "2026-10-09T15:00:00.000+05:30",
"count": 3600, "avg": 11.42, "min": 0.38, "max": 14.9,
"bad_count": 0 …
},
…
]
}Guides
- Monitor old CNC machines without replacing the controllerRead
- MTConnect vs OPC UA: which to use for machine dataRead
- Modbus energy monitoring: meter a machine per circuitRead
- Machine utilisation: measure running, idle and off timeRead
- Predictive maintenance for machine shops: a plain guideRead
- ISO 20816-3 vibration zones: what A, B, C and D meanRead