Next
Predictive maintenance for pharmaceuticals.
An air-handler fan bearing wearing out before a clean room loses its pressure, with every fix on an audit trail.
Who it is for
Formulation plants, API units and the clean-room utilities behind them.
Next
Next on our list, where we go after the pilot. The pumps, motors and compressors in pharmaceuticals plants are machine classes Atlas Edge already models; machines such as air handling units and purified water loops need their own signals and limits first. We are looking for design partners: plants that want to shape it and run it first.
What it listens to
Air handling units
Watches · Fan vibration
Purified water loops
Watches · Loop flow
Tablet presses
Watches · Main drive load
Chillers
Watches · Supply temperature
What goes wrong first
The first sign, and how it is caught.
| Fault | The first sign | How Atlas Edge watches it |
|---|---|---|
| Air-handler fan bearing or belt wear | Fan vibration rising out of its zone before airflow drops | ISO 20816-3 vibration zone and change from its reference |
| Purified water pump wear | Loop flow or pressure falling at the same pump power | Alarm at your limit, raised only after a hold time |
| Tablet press drive strain | Main drive load higher for the same output | Learned normal for its load: Watch, then Investigate |
| Chiller losing capacity | Supply temperature drifting up on the same load | Weekly trend in the KPI view and the monthly report |
How a zone is judged: ISO 20816-3 vibration zones. Why alarms wait: hold time and deadband.
How maintenance works here
In a pharmaceutical plant the machines that matter most are often the utilities behind production: air handling units that hold clean-room pressure, purified water loops, chillers and compressed air. When one of them drifts, a batch can be at risk before anything has visibly broken.
Everything happens under GMP. A deviation needs a record, changes go through change control, and computerised systems that make GMP decisions must be validated. So a maintenance view of machine condition sits beside the plant's qualified environmental monitoring system; it does not replace it.
Where it stands
- Pharmaceuticals is next on our list, not built as a sector yet. The pumps, motors and compressors in these plants are machine classes the dashboard already models.
- Every action (a lockout, a work order step, an acknowledged alarm, a changed limit) goes into an activity log with who did it and when, readable as a sentence and exportable to Excel.
- It is not a validated GxP system and does not replace a qualified environmental monitoring system.
Standards people in pharmaceuticals work to
- EudraLex Volume 4, EU GMP and Annex 11 (European Commission)
Annex 11 covers validation, audit trails and data integrity of computerised systems.
- 21 CFR Part 11 guidance (US FDA)
Electronic records and signatures in FDA-regulated work.
- ISO 14644 cleanrooms (iso.org)
Cleanroom classification and the monitoring that keeps a room in class.
- ISPE GAMP 5 (ispe.org)
A risk-based approach to computerised systems in GxP work.
Listed so you know what applies; Atlas Edge claims no certification against them.
Same platform underneath
Everything our pilot floor runs on, for your floor.
Live views
Every machine's readings as they happen, beside a cutaway drawing of it, on every screen at once.
Load-aware anomaly detection
Learns how each reading moves with the load and says Normal, Watch or Investigate, with the reason in plain words.
Alarms that hold
A condition must hold before it raises, escalates from warning to critical, and clears only past a deadband.
Work orders & LOTO
Verified, approved, PIN-gated lockouts, and the cause of every stop recorded on release.
KPIs & OEE
Availability, MTBF, MTTR, OEE, energy and downtime by cause, per machine, area and plant.
Monthly report
A performance report with an Excel workbook in the inbox on the 1st of every month.
Reads FANUC, SINUMERIK, Mazak, Okuma and Haas over MTConnect, Siemens S7-1500 over OPC UA, Rockwell Logix PLCs over EtherNet/IP, energy meters and drives over Modbus RTU/TCP, and sensors over MQTT. Every feature
Pharmaceuticals
Common questions.
Does Atlas Edge work with air handling units?
Not yet as a machine class of its own: pharmaceuticals is next on our list. Their pumps, motors and compressors can be monitored as those classes, and we are looking for design partners to build the rest with.
Do we have to replace our PLCs or controllers?
No. Atlas Edge reads from what you already have, over Modbus RTU/TCP, MTConnect, OPC UA, EtherNet/IP, MQTT or HTTP/JSON, through one edge gateway per shop area, and never changes a program or setting. Only the E1 Reflex model can also ask a machine to stop, when a limit you set is crossed.
What does it catch in pharmaceuticals?
An air-handler fan bearing wearing out before a clean room loses its pressure, with every fix on an audit trail. It learns each machine's normal from its own running hours, flags a drift in plain words and projects the trend to the warning limit, labelled an estimate.
How do we start?
Write to us about your plant and its machines. Design partners in pharmaceuticals get it first and shape what it watches.
Guides
- Predictive maintenance for machine shops: a plain guideRead
- ISO 20816-3 vibration zones: what A, B, C and D meanRead
- Nuisance alarms: stop chattering with a hold time and deadbandRead
- MTBF and MTTR: what they mean and how to calculate themRead
- Machine downtime tracking: record why every stop happenedRead
Other industries
Bring your plant alive.
A gateway per shop area, the controllers you already have, and your first monthly report in the inbox on the 1st. Tell us about your floor.