Atlas Edge E1 · industrial IoT edge gateway:E1.
The box that reads your floor.
One in each shop area, on the DIN rail of a panel you already have. It reads every machine around it, as often as every second, and sends it to the dashboard. E1 Reflex can also ask a machine to stop.
Two models. One board.
They read machines the same way. The difference is what happens when a reading crosses the line: E1 tells your team, and E1 Reflex also asks the machine to stop.
- E1PWRRUNCOMMFAULTATLAS EDGE
E1
Reads every machine in a shop area and sends it to the dashboard. It watches; your team acts.
- Can't stop a machine: it has no outputs. It tells your team, and a person decides
- Warnings and alarms go to the right people, by email and in the dashboard
- Two isolated, surge-protected RS-485 ports, two Ethernet ports and four digital inputs
- No output parts are fitted, so no update or setting can ever make it act: the simplest approval with plant IT
- E1ReflexPWRRUNCOMMFAULTARMEDTRIPPEDATLAS EDGE
E1 Reflex
Everything E1 does, and when a limit you set is crossed, it asks the machine to stop.
- Two relay outputs ask your machine's own controller for a feed hold or cycle stop
- Four isolated, surge-protected RS-485 ports, eight digital inputs and two 4–20 mA inputs
- Decides on the box, so a dropped internet line never clears a stop
- ARMED and TRIPPED lamps, a reset button and a key in your panel
- Every trip recorded with its cause, a black box of the moments around it, and how fast the machine answered
- Two vibration inputs, and a finish coated against coolant mist and dust
Both models have
Set up from the dashboard
Machines and signals are added in the dashboard, with a test read of each one before it is saved. No one edits files on the box.
32 GB built in
Through an internet outage, readings wait inside the box, then go home without duplicates once the line is back.
Six protocols
The controllers, PLCs, meters and drives already on your floor, old ones included.
Updates itself
Signed software from the dashboard. If an update fails to report in, it goes back to the last one.
Only on E1 Reflex.
Reflex is a wider module with more on it: the outputs that ask for a stop, inputs it reads itself, and the panel and records a stop needs.
- Reflex
Stop-request outputs
Two relays ask your machine's own controller for a feed hold or cycle stop, and a warning output lights a lamp or sounds a horn first.
- Reflex
Two 4–20 mA inputs
A transmitter wired straight to Reflex is checked on the box, without waiting for a network poll.
- Reflex
Eight digital inputs
Enough for the machine's handshake (running, stop acknowledged, reset) and its status signals. E1 has four.
- Reflex
A front panel for stops
ARMED and TRIPPED lamps and a reset button, so the state is clear at the panel. The machine is restarted at the machine.
- Reflex
Trip records and a test trip
Every trip is kept with the reading that caused it. A test trip proves the wiring at commissioning.
- Reflex
Two power inputs
Runs on either of two 24 V supplies. If one fails, Reflex tells you and keeps going.
- Reflex
A black box for every trip
Keeps the moments before and after each trip, with the limit that went first. It reaches the dashboard with the trip, so you can see what really happened.
- Reflex
Two vibration inputs
Takes standard vibration sensors (IEPE accelerometers) and a speed signal. Reflex works out the overall vibration and its frequency bands on the box.
- Reflex
A coated finish
Coated against coolant mist, dust and damp, where E1 has a standard industrial finish.
Compare the models.
Planned specifications. Subject to change until the first units are built and tested.
| E1 | E1 Reflex | |
|---|---|---|
| Serial | 2 × RS-485 | 4 × RS-485 |
| Digital inputs | 4 × isolated 24 V | 8 × isolated 24 V |
| Analog inputs | No | 2 × 4–20 mA |
| Vibration inputs | No | 2 + a speed input |
| Can it stop a machine | No | Yes, when a limit you set is crossed |
| Ethernet | Both models2 × Gigabit | |
| Wi-Fi and Bluetooth | Both modelsPlanned | |
| Memory | 4 GB | 8 GB |
| Storage | 32 GB built in | 64 GB built in |
| Through a restart or update of the box | Readings pause | Stops, the latch and the 4–20 mA limits carry on |
| Power | One 24 V DC input | Two 24 V DC inputs |
| Operating temperature | Target: −20 to +60 °C | Target: −25 to +50 °C |
See all 38 specificationsHide the full specifications
| E1 | E1 Reflex | |
|---|---|---|
| Reading machines | ||
| Protocols | Both models | |
| Serial | 2 × RS-485Isolated, with surge protection on every port (design, to be tested) | 4 × RS-485Isolated, with surge protection on every port (design, to be tested) |
| Fastest reading | Once a secondEvery machine, as often as once a second | Once a secondEvery machine, as often as once a second; 0.1 s for the signals that feed a limit (planned) |
| Digital inputs | 4 × isolated 24 VMachine running, door, stack light | 8 × isolated 24 VMachine running, stop acknowledged, reset, status |
| Analog inputs | Not on E1 | 2 × 4–20 mAIsolated |
| Vibration inputs | Not on E1 | 2 + a speed inputFor standard vibration sensors (IEPE accelerometers). Overall vibration (10–1,000 Hz, the ISO measure) and frequency bands worked out on the box |
| Commissioning | A test read of each connection | Plus a test trip that times the machine's answer |
| Asking for a stop | ||
| Can it stop a machine | NoIt alerts your team | Yes, when a limit you set is crossedIt asks the machine's own controller for a feed hold or cycle stop |
| Outputs | NoneNo output parts are fitted, so none can be added by software | 2 relaysSTOP request and READY, plus a warning output for a lamp or horn |
| What trips it | Not on E1 | A limit you set, held for a time you setLearned warnings alert people; they never stop a machine on their own |
| Where it decides | Not on E1 | On the box, with or without the internetNothing in the cloud can switch an output |
| After a trip | Not on E1 | Stays tripped until a person resets itIt never restarts a machine |
| Arming | Not on E1 | Key switch in your panelOutputs stay inactive until armed |
| Changing a limit | Not on E1 | Signed by the dashboard and confirmed by a second personEvery change is recorded |
| If the box fails | Not on E1 | Its outputs drop on power loss or a faultYour controller decides what that means |
| Front panel | Power, run, comms and fault lamps | Plus ARMED and TRIPPED lampsAnd a reset button |
| Records | Readings and alarms | Plus every trip and its causeWith the reading, how fast the machine answered, and every power cut |
| Black box | Not on E1 | The 30 s before each trip and the 10 s afterWith the limit that went first. Sent to the dashboard with the trip |
| Safety rating | Not on E1 | NoneNot a safety device and never part of an emergency-stop or guard circuit |
| Connecting home | ||
| Ethernet | Both models2 × Gigabit | |
| Wi-Fi and Bluetooth | Both modelsPlannedWi-Fi where there is no cable, and Bluetooth LE for wireless sensors, through an antenna connector on the front panel. Working as a Wi-Fi access point is to be confirmed. Wired Ethernet stays | |
| Clock | Both modelsPTP (IEEE 1588) or NTPTakes precise time from the plant network, so readings from every box line up. A battery-backed clock keeps time through power cuts | |
| Dashboard | Everything: monitoring, alarms, work orders, KPIs, OEE, reports, data API | The same, plus the Reflex panelArmed state, limits, trips and test trips (planned) |
| The box | ||
| Processor | Both modelsQuad-coreIndustrial grade | |
| Memory | 4 GB | 8 GB |
| Storage | 32 GB built in | 64 GB built in |
| Through an internet outage | Keeps readingStores the readings on the box and sends them when the connection is back | The same, and keeps warning and asking for stopsThose decisions never need the internet |
| Through a restart or update of the box | Readings pause | Stops, the latch and the 4–20 mA limits carry onA second, separate processor keeps them running |
| Recovers on its own | Both modelsYesA watchdog restarts it if it ever hangs | |
| Security | Both modelsA security chipFor the box's identity and signed updates | |
| Updates | SignedWith automatic rollback if a new version fails | SignedWith automatic rollback if a new version fails; the stop processor's firmware too, applied only while disarmed (planned) |
| In the panel | ||
| Power | One 24 V DC input | Two 24 V DC inputsEither runs it, and losing one is reported, not a stop |
| Mounting | Both models35 mm DIN rail | |
| Size and front | The narrower module, light greyWith no output terminals | A wider module, black frontWith the output block, ARMED and TRIPPED lamps and RESET on the front |
| Enclosure | Both modelsIP20For control cabinets | |
| Operating temperature | Target: −20 to +60 °CTo be tested | Target: −25 to +50 °CTo be tested |
| Finish | Standard industrial finish | CoatedAgainst coolant mist, dust and damp |
| Approvals | ||
| Certification | PlannedIndustrial EMC and product safety, CE | PlannedAs E1, including its outputs |
E1 Reflex
When a warning can't wait.
Some faults grow too fast for a phone call: a bearing running hot, a spindle load that keeps climbing, coolant pressure falling away. E1 Reflex catches them on the box and asks the machine to stop while the fault is still small, whether or not anyone is looking at a screen.
- 01
You set the limit
A signal, a limit and how long it must hold: say, spindle bearing above 75 °C for 30 seconds. Learned warnings never trip it; they go to people.
- 02
The box decides
Every reading is checked against your limits on the box itself, so a dropped internet line changes nothing. Nothing in the cloud can switch an output.
- 03
It asks for a stop
A relay asks your machine's own controller for a feed hold or cycle stop. The controller decides how the machine stops.
- 04
A person takes over
The stop holds until someone resets it, and Reflex never restarts a machine. Every arming, trip and reset is recorded, and the alarm opens as usual.
What Reflex is not. It is a stop request, not a safety device. Your machine's emergency stops, guards and protection stay in charge, and your integrator decides how it is wired. It is made for faults that build over seconds, like heat, load and pressure, not a tool breaking mid-cut.
Simple prices.
Shown in Indian rupees.
Dashboard
₹1,790
per machine, per month, billed monthly
or ₹1,490 a month billed yearly
E1
₹59,900
paid once, per box
E1 Reflex
₹99,900
paid once, per box
Founding customers: our first 10 customers pay ₹990 per machine, per month, locked for life, on a yearly plan.
E1 is being designed now. Tell us about your floor and we'll tell you which model fits it.
Bring your plant alive.
A gateway per shop area, the controllers you already have, and your first monthly report in the inbox on the 1st. Tell us about your floor.