Skip to content

Atlas Edge E1 · industrial IoT edge gateway:E1.

The box that reads your floor.

One in each shop area, on the DIN rail of a panel you already have. It reads every machine around it, as often as every second, and sends it to the dashboard. E1 Reflex can also ask a machine to stop.

Two models. One board.

They read machines the same way. The difference is what happens when a reading crosses the line: E1 tells your team, and E1 Reflex also asks the machine to stop.

Both models have

Only on E1 Reflex.

Reflex is a wider module with more on it: the outputs that ask for a stop, inputs it reads itself, and the panel and records a stop needs.

Compare the models.

Planned specifications. Subject to change until the first units are built and tested.

E1 and E1 Reflex compared, planned specifications, at a glance
E1E1 Reflex
Serial2 × RS-4854 × RS-485
Digital inputs4 × isolated 24 V8 × isolated 24 V
Analog inputsNo2 × 4–20 mA
Vibration inputsNo2 + a speed input
Can it stop a machineNoYes, when a limit you set is crossed
EthernetBoth models2 × Gigabit
Wi-Fi and BluetoothBoth modelsPlanned
Memory4 GB8 GB
Storage32 GB built in64 GB built in
Through a restart or update of the boxReadings pauseStops, the latch and the 4–20 mA limits carry on
PowerOne 24 V DC inputTwo 24 V DC inputs
Operating temperatureTarget: −20 to +60 °CTarget: −25 to +50 °C
See all 38 specificationsHide the full specifications
E1 and E1 Reflex compared, planned specifications
E1E1 Reflex
Reading machines
ProtocolsBoth models
  • Modbus RTU and TCP
  • OPC UA
  • MQTT and Sparkplug B
  • EtherNet/IP
  • MTConnect
  • HTTP/JSON
Serial2 × RS-485Isolated, with surge protection on every port (design, to be tested)4 × RS-485Isolated, with surge protection on every port (design, to be tested)
Fastest readingOnce a secondEvery machine, as often as once a secondOnce a secondEvery machine, as often as once a second; 0.1 s for the signals that feed a limit (planned)
Digital inputs4 × isolated 24 VMachine running, door, stack light8 × isolated 24 VMachine running, stop acknowledged, reset, status
Analog inputsNot on E12 × 4–20 mAIsolated
Vibration inputsNot on E12 + a speed inputFor standard vibration sensors (IEPE accelerometers). Overall vibration (10–1,000 Hz, the ISO measure) and frequency bands worked out on the box
CommissioningA test read of each connectionPlus a test trip that times the machine's answer
Asking for a stop
Can it stop a machineNoIt alerts your teamYes, when a limit you set is crossedIt asks the machine's own controller for a feed hold or cycle stop
OutputsNoneNo output parts are fitted, so none can be added by software2 relaysSTOP request and READY, plus a warning output for a lamp or horn
What trips itNot on E1A limit you set, held for a time you setLearned warnings alert people; they never stop a machine on their own
Where it decidesNot on E1On the box, with or without the internetNothing in the cloud can switch an output
After a tripNot on E1Stays tripped until a person resets itIt never restarts a machine
ArmingNot on E1Key switch in your panelOutputs stay inactive until armed
Changing a limitNot on E1Signed by the dashboard and confirmed by a second personEvery change is recorded
If the box failsNot on E1Its outputs drop on power loss or a faultYour controller decides what that means
Front panelPower, run, comms and fault lampsPlus ARMED and TRIPPED lampsAnd a reset button
RecordsReadings and alarmsPlus every trip and its causeWith the reading, how fast the machine answered, and every power cut
Black boxNot on E1The 30 s before each trip and the 10 s afterWith the limit that went first. Sent to the dashboard with the trip
Safety ratingNot on E1NoneNot a safety device and never part of an emergency-stop or guard circuit
Connecting home
EthernetBoth models2 × Gigabit
Wi-Fi and BluetoothBoth modelsPlannedWi-Fi where there is no cable, and Bluetooth LE for wireless sensors, through an antenna connector on the front panel. Working as a Wi-Fi access point is to be confirmed. Wired Ethernet stays
ClockBoth modelsPTP (IEEE 1588) or NTPTakes precise time from the plant network, so readings from every box line up. A battery-backed clock keeps time through power cuts
DashboardEverything: monitoring, alarms, work orders, KPIs, OEE, reports, data APIThe same, plus the Reflex panelArmed state, limits, trips and test trips (planned)
The box
ProcessorBoth modelsQuad-coreIndustrial grade
Memory4 GB8 GB
Storage32 GB built in64 GB built in
Through an internet outageKeeps readingStores the readings on the box and sends them when the connection is backThe same, and keeps warning and asking for stopsThose decisions never need the internet
Through a restart or update of the boxReadings pauseStops, the latch and the 4–20 mA limits carry onA second, separate processor keeps them running
Recovers on its ownBoth modelsYesA watchdog restarts it if it ever hangs
SecurityBoth modelsA security chipFor the box's identity and signed updates
UpdatesSignedWith automatic rollback if a new version failsSignedWith automatic rollback if a new version fails; the stop processor's firmware too, applied only while disarmed (planned)
In the panel
PowerOne 24 V DC inputTwo 24 V DC inputsEither runs it, and losing one is reported, not a stop
MountingBoth models35 mm DIN rail
Size and frontThe narrower module, light greyWith no output terminalsA wider module, black frontWith the output block, ARMED and TRIPPED lamps and RESET on the front
EnclosureBoth modelsIP20For control cabinets
Operating temperatureTarget: −20 to +60 °CTo be testedTarget: −25 to +50 °CTo be tested
FinishStandard industrial finishCoatedAgainst coolant mist, dust and damp
Approvals
CertificationPlannedIndustrial EMC and product safety, CEPlannedAs E1, including its outputs

E1 Reflex

When a warning can't wait.

Some faults grow too fast for a phone call: a bearing running hot, a spindle load that keeps climbing, coolant pressure falling away. E1 Reflex catches them on the box and asks the machine to stop while the fault is still small, whether or not anyone is looking at a screen.

  1. 01

    You set the limit

    A signal, a limit and how long it must hold: say, spindle bearing above 75 °C for 30 seconds. Learned warnings never trip it; they go to people.

  2. 02

    The box decides

    Every reading is checked against your limits on the box itself, so a dropped internet line changes nothing. Nothing in the cloud can switch an output.

  3. 03

    It asks for a stop

    A relay asks your machine's own controller for a feed hold or cycle stop. The controller decides how the machine stops.

  4. 04

    A person takes over

    The stop holds until someone resets it, and Reflex never restarts a machine. Every arming, trip and reset is recorded, and the alarm opens as usual.

What Reflex is not. It is a stop request, not a safety device. Your machine's emergency stops, guards and protection stay in charge, and your integrator decides how it is wired. It is made for faults that build over seconds, like heat, load and pressure, not a tool breaking mid-cut.

Simple prices.

Shown in Indian rupees.

Founding customers: our first 10 customers pay ₹990 per machine, per month, locked for life, on a yearly plan.

Tell me when E1 ships.

E1 and E1 Reflex are still being built, so there is no date yet and we take no orders or money for them. Leave your email and we will write to you when they ship.

No payment, no order and no date. Used only to tell you when E1 ships. Privacy

E1 is being designed now. Tell us about your floor and we'll tell you which model fits it.

Bring your plant alive.

A gateway per shop area, the controllers you already have, and your first monthly report in the inbox on the 1st. Tell us about your floor.