How bad is that vibration?

How ISO 20816-3 judges the vibration of industrial machines above 15 kW: what to measure, the zone boundaries in mm/s, rigid and flexible supports, and why a change from the machine's own reference matters as much as the zone it is in.

3 min read · Updated 24 November 2026

What the standard judges

ISO 20816-3:2022 is the standard most plants use to say whether a running machine's vibration is acceptable. It covers coupled industrial machines with a power rating above 15 kW and speeds between 120 and 30 000 r/min, measured in place, and it replaced ISO 10816-3:2009 and ISO 7919-3:2009. A second edition is due in 2026.

It judges broadband vibration velocity in mm/s r.m.s., measured on the bearing housings, in two directions at right angles to the shaft, while the machine runs steadily at its normal load. For most machines the band is 10 Hz to 1 000 Hz; slow machines need a lower start.

  • Not covered: machines of 15 kW and below.
  • Not covered: rotary positive displacement compressors such as screw compressors.
  • Not covered: rotodynamic pumps with the impeller on the motor shaft, which ISO 10816-7 covers.
  • Not listed: machine tools. Judge them against the maker's limits instead.

Group and support set the limits

Two facts about the machine pick its limits. Its group: group 1 is above 300 kW, group 2 above 15 kW up to 300 kW. And its support: a support counts as rigid in a direction when the lowest natural frequency of the machine on its support is at least 25 % above the main excitation frequency, usually the running speed; anything else is flexible. A heavy motor bolted to a concrete plinth is usually rigid; the same motor on a steel frame or rubber mounts is often flexible.

When you do not know the support, judge it as rigid. Its limits are lower, so the mistake errs on the side of looking.

The zone boundaries

Each group and support has three boundaries, which split readings into four zones:

Velocity in mm/s r.m.s. These are the figures published for ISO 10816-3:2009 (Annex A), which ISO 20816-3 replaced. Check them against your copy of the current standard before you write them into a contract or an acceptance test.
MachineA/BB/CC/D
Group 2 (15–300 kW), rigid1.42.84.5
Group 2 (15–300 kW), flexible2.34.57.1
Group 1 (above 300 kW), rigid2.34.57.1
Group 1 (above 300 kW), flexible3.57.111.0

What each zone means

  • Zone A: where newly commissioned machines normally read.
  • Zone B: acceptable for long-term running.
  • Zone C: normally unsatisfactory for long-term continuous running. Plan a repair at the next chance.
  • Zone D: normally severe enough to cause damage.

The second test: change from the machine's own reference

A zone alone misses a lot. A machine that has always read 1.0 mm/s and now reads 2.0 mm/s is still in zone B, and something has changed. So the standard adds a second criterion: a change of more than 25 % of the B/C boundary, up or down, from the machine's reference value is significant, even inside zone B, and calls for a look.

An example, with made-up figures: a 55 kW motor on a concrete base is group 2, rigid, so its B/C boundary is 2.8 mm/s and a significant change is 0.7 mm/s. It was accepted at 1.1 mm/s. Today it reads 1.9 mm/s: comfortably in zone B, but 0.8 mm/s up from its reference. Investigate.

The reference should be a figure someone accepted: the maker's acceptance test, or the machine's own steady level once someone has checked that it was healthy. A level learnt from whatever the machine happened to do last month is not a reference; it may already include the fault.

Peers: the next best thing to a reference

Where nobody has a reference yet, identical machines doing similar work help. If three or more of the same model read around 1.2 mm/s and one reads 2.0 mm/s, that one deserves a look. It is a reason to look, not proof: mountings and jobs differ. A machine reading below its peers is not a sign of a fault by itself.

How Atlas Edge uses it

Atlas Edge judges vibration from a machine's first running hours. Motors and geared machines above 15 kW are placed in their ISO 20816-3 zone; machines the standard does not cover are judged against their own warning and trip limits, and the screen says which basis it used and why.

A reference is entered or accepted by a person, never learnt. A significant change from that reference, or a machine reading well above identical machines doing similar work, is flagged on its condition panel and in the monthly report. These are for the maintenance team to read; they do not raise alarms on their own.

Sources

Guide

Quick answers.

What is a good vibration level for an electric motor?

For a motor of 15 to 300 kW on a rigid base, below 1.4 mm/s r.m.s. is zone A, where a new machine normally reads, and up to 2.8 mm/s is acceptable for long-term running (the ISO 10816-3 figures; check your copy of ISO 20816-3). Just as important is how far it has moved from its own accepted reference.

Is ISO 10816-3 still valid?

It has been withdrawn. ISO 20816-3:2022 replaced ISO 10816-3:2009 and ISO 7919-3:2009, and a second edition of ISO 20816-3 is due in 2026.

Should vibration be measured as velocity or acceleration?

ISO 20816-3 judges overall severity in velocity, mm/s r.m.s. Acceleration and envelope measurements are better at catching early bearing defects; many plants use velocity for severity and add those for diagnosis.