Utilisation is a count of minutes
Ask a shop how busy its machines are and you will hear a guess. Utilisation replaces the guess with a count: of the hours a machine could have worked, how many did it actually spend working? The hard part is not the division. It is deciding, minute by minute, what “working” means, and doing it the same way on every machine.
Read the state from power
A machine's power draw says what it is doing without anyone writing anything down. Compare each minute's average power with the machine's rated power. With a common split like this one, three states fall out:
- Running: at least 10 % of rated power. The spindle, the pump or the drive is doing work.
- Idle: above 2 % and below 10 %. Powered up and waiting: hydraulics, coolant and drives on, no cut.
- Off: at or below 2 %. Control power only, or nothing.
| State | Share of rated power | Average power in the minute |
|---|---|---|
| Running | 10 % or more | 1.5 kW or more |
| Idle | above 2 %, below 10 % | above 0.3 kW, below 1.5 kW |
| Off | 2 % or less | 0.3 kW or less |
Missing data is not off
When a meter or a gateway stops reporting, the tempting shortcut is to treat the silence as the machine being off. It quietly lowers utilisation for reasons that have nothing to do with production. Keep a separate state for minutes with no reading, and show it as no data.
Time the machine was locked out for maintenance, or taken out of service, is not idle either. Take it from the lockout record, so it overrides whatever the power reading says.
Machines without a power meter
Many CNC controllers and PLCs already report what they are doing: running, idle, feed hold, stopped on an alarm, emergency stop. Where there is no power reading, use that instead: running counts as running, off as off, and everything in between as idle. Where both are read, prefer power: it shows a machine that is “in cycle” but not cutting.
Calculate utilisation
Run hours = running minutes / 60. Utilisation % = run hours / uptime hours × 100, where uptime is the time the machine was available: the period, minus the time it was locked out or out of service. Dividing by uptime rather than by the calendar keeps breakdowns out of the utilisation figure; they belong in availability.
An example, with made-up figures: in a 30-day month (720 hours) a grinder was locked out for 20 hours, so its uptime was 700 hours. It ran for 385 of them. Utilisation = 385 / 700 = 55 %.
Hours with no reading at all should stay unknown in the figures, not count as zero. A utilisation figure is only as good as the share of hours it was measured on, so show that share beside it.
How Atlas Edge does it
Atlas Edge sorts every minute of every connected machine into Running, Idle, Off, Locked out, Decommissioned or No data, from its power against its rating, the controller's run state for machines read without a meter, and the lockout record overriding both. Run hours, utilisation (run hours over uptime) and a state timeline per machine and for the plant are on the Maintenance KPIs view, and the monthly Excel report has the state hours per day. Hours without data are shown as “No data recorded”, never as 0.