The two numbers
Together they describe reliability (how often a machine stops) and maintainability (how long it stays stopped).
- MTBF (mean time between failures) = uptime / number of failures. Higher is better: the machine runs longer between breakdowns.
- MTTR (mean time to repair) = total repair time / number of repairs. Lower is better: when it breaks, it is back sooner.
First decide what a failure is
This is where most MTBF figures go wrong. If every stop counts, planned servicing makes a well-maintained machine look unreliable. If only big breakdowns count, the figure flatters.
Atlas Edge counts a failure as an unplanned lockout: one tripped by a rule or applied in an emergency. A lockout under a planned work order is maintenance, not a failure. Write your own definition down and keep it the same every month.
A worked example
An example, with made-up figures: in a 30-day month a compressor was registered for 720 hours. It was locked out for 18 hours in all, so its uptime was 702 hours. Two of those lockouts were failures: one released after 4 hours, one after 8.
MTBF = 702 / 2 = 351 hours. MTTR = (4 + 8) / 2 = 6 hours. Availability = 702 / 720 = 97.5 %.
Getting honest numbers
- Take the times from the lockout record (lockout to release), not from memory at the end of the month.
- With no failures in the month there is no MTBF to report. Say so instead of dividing by zero or writing infinity.
- A failure still locked out has no repair time yet; leave it out of MTTR until it is released.
- Record the cause of every stop when the machine is released. MTTR by cause (mechanical, electrical, waiting for parts) tells you where the hours actually go.
A month of lockouts, worked through
An example, with made-up figures: one compressor's lockout record for a 30-day month (720 hours). Only the unplanned ones count as failures.
| Lockout | Under | Hours | Failure? |
|---|---|---|---|
| 3rd, 06:00 | Planned order: oil and filter change | 3 | No |
| 11th, 14:20 | Rule trip: discharge temperature critical | 4 | Yes |
| 19th, 09:00 | Planned order: separator element | 3 | No |
| 24th, 22:10 | Emergency order: drive fault | 8 | Yes |
| Month | 4 lockouts | 18 | 2 failures |
Edge cases
- Several machines together: add up the uptime and the failures across them, then divide (720 h and 2 failures plus 700 h and 1 failure gives 1,420 / 3 = 473 h). Averaging each machine's MTBF gives a different, wrong number.
- A failure that starts in one month and ends in the next: count the failure in the month it started, and split its hours by month for availability.
- MTBF or MTTF: MTTF (mean time to failure) is for things that are replaced, not repaired, such as a bearing or a fuse. For a machine you repair, use MTBF.
- MTBF is an average, not a promise. An MTBF of 351 hours does not mean the next failure comes in 351 hours; it describes the past, and a short period with two failures says little.
- Uptime counts registered time, not running time: a machine that is available but idle is still up. Some plants use run hours instead; either works if the report says which.
How Atlas Edge works them out
Atlas Edge calculates availability, MTBF and MTTR per machine, area and plant every month from its lockout/tagout trail. Releasing a lockout asks for the cause of the downtime, so downtime by cause comes out as a Pareto chart, and the monthly report's Excel workbook carries the same figures with their formulas.