Next
Predictive maintenance for steel & foundries.
A furnace cooling-water pump losing flow before an induction coil overheats.
Who it is for
Foundries, induction melting shops, re-rolling mills and forging units.
Next
Next on our list, where we go after the pilot. The pumps, motors and compressors in steel & foundries plants are machine classes Atlas Edge already models; machines such as induction furnaces and rolling mill drives need their own signals and limits first. We are looking for design partners: plants that want to shape it and run it first.
What it listens to
Induction furnaces
Watches · Coil water temperature
Rolling mill drives
Watches · Drive current
Cooling water pumps
Watches · Flow
EOT cranes
Watches · Hoist motor temperature
What goes wrong first
The first sign, and how it is caught.
| Fault | The first sign | How Atlas Edge watches it |
|---|---|---|
| Induction coil cooling loss | Coil water temperature rising or flow falling | Alarm at your limit, raised only after a hold time |
| Cooling water pump wear | Flow dropping at the same pump power | Learned normal for its load: Watch, then Investigate |
| Rolling mill drive strain | Drive current higher for the same pass | Learned normal for its load: Watch, then Investigate |
| EOT crane hoist motor overheating | Hoist motor temperature climbing shift over shift | Weekly trend in the KPI view and the monthly report |
How a zone is judged: ISO 20816-3 vibration zones. Why alarms wait: hold time and deadband.
Same platform underneath
Everything our pilot floor runs on, for your floor.
Live views
Every machine's readings as they happen, beside a cutaway drawing of it, on every screen at once.
Load-aware anomaly detection
Learns how each reading moves with the load and says Normal, Watch or Investigate, with the reason in plain words.
Alarms that hold
A condition must hold before it raises, escalates from warning to critical, and clears only past a deadband.
Work orders & LOTO
Verified, approved, PIN-gated lockouts, and the cause of every stop recorded on release.
KPIs & OEE
Availability, MTBF, MTTR, OEE, energy and downtime by cause, per machine, area and plant.
Monthly report
A performance report with an Excel workbook in the inbox on the 1st of every month.
Reads FANUC, SINUMERIK, Mazak, Okuma and Haas over MTConnect, Siemens S7-1500 over OPC UA, Rockwell Logix PLCs over EtherNet/IP, energy meters and drives over Modbus RTU/TCP, and sensors over MQTT. Every feature
Steel & foundries
Common questions.
Does Atlas Edge work with induction furnaces?
Not yet as a machine class of its own: steel & foundries is next on our list. Their pumps, motors and compressors can be monitored as those classes, and we are looking for design partners to build the rest with.
Do we have to replace our PLCs or controllers?
No. Atlas Edge reads from what you already have, over Modbus RTU/TCP, MTConnect, OPC UA, EtherNet/IP, MQTT or HTTP/JSON, through one edge gateway per shop area, and never changes a program or setting. Only the E1 Reflex model can also ask a machine to stop, when a limit you set is crossed.
What does it catch in steel & foundries?
A furnace cooling-water pump losing flow before an induction coil overheats. It learns each machine's normal from its own running hours, flags a drift in plain words and projects the trend to the warning limit, labelled an estimate.
How do we start?
Write to us about your plant and its machines. Design partners in steel & foundries get it first and shape what it watches.
Guides
- Monitor old CNC machines without replacing the controllerRead
- Predictive maintenance for machine shops: a plain guideRead
- ISO 20816-3 vibration zones: what A, B, C and D meanRead
- How to calculate OEE (and the mistakes that inflate it)Read
- MTBF and MTTR: what they mean and how to calculate themRead
- Machine downtime tracking: record why every stop happenedRead
- Machine utilisation: measure running, idle and off timeRead
- Nuisance alarms: stop chattering with a hold time and deadbandRead
- OEE calculator: availability, performance and qualityRead
- MTBF and MTTR calculator for machinesRead
- MTConnect vs OPC UA: which to use for machine dataRead
- Modbus energy monitoring: meter a machine per circuitRead
- MachineMetrics alternative: how Atlas Edge comparesRead
- Evocon alternative: how Atlas Edge comparesRead
Other industries
Bring your plant alive.
A gateway per shop area, the controllers you already have, and your first monthly report in the inbox on the 1st. Tell us about your floor.